Configuring the AS-Interface safety monitor
4.3 Creating and changing a configuration
ASIMON V3 - Configuration software for AS-Interface safety monitor
128 Programming and Operating Manual, Edition 09/2008, GWA 4NEB 333 1558 02 DS 02
Configuration loglExample: with unlocking device
0043 INDEX: 36 = "Name"
0044 TYPE: 104 = door lock and stop 1 with delayed relay
0045 ASSIGNED: channel one
0046 SUBTYPE: time
0047 STOP1 DELAY: 10.000 Sec
0048 UNLOCK DLY : 20.000 Sec
0049 LOCK: yes ADDRESS: 20 BIT: In-0 noninv
3
4
5
6
7
8
9
Example: without unlocking device
0043 INDEX: 36 = "Name"
0044 TYPE: 104 = door lock and stop 1 with delayed relay
0045 ASSIGNED: channel one
0046 SUBTYPE: time
0047 STOP1 DELAY: 10.000 Sec
0048 UNLOCK DLY : 20.000 Sec
0049 LOCK: no
3
4
5
6
7
8
9
Example: Without unlocking device, safe AS-i output
0053 INDEX: 37 = "Name"
0054 TYPE: 104 = door lock and stop 1 with delayed relay
0055 ASSIGNED: channel one
0056 SUBTYPE: time
0057 STOP1 DELAY: 10.000 Sec
0058 UNLOCK DLY : 20.000 Sec
0059 LOCK: no
0060 SAFE ACTUATOR ADDRESS 27
0061 Help Signal 1 from Device 35 at switching ON
0062 Help Signal 2 from Device 1 at switching ON
3
4
5
6
7
8
9
0
1
0