Configuring the AS-Interface safety monitor
4.3 Creating and changing a configuration
ASIMON V3 - Configuration software for AS-Interface safety monitor
Programming and Operating Manual, Edition 09/2008, GWA 4NEB 333 1558 02 DS 02 69
Description
The monitor input monitoring device is used to link a signal to one of the inputs 1.Y1 through
2.Y2 of the AS-Interface safety monitor as an additional switching signal for operational
switching of the AS-Interface safety monitor relay(s) in an OSSD.
The state of the device corresponds to the level at the selected monitor input. In order to chan-
ge the state of the device, the level at the selected monitor input must remain stable for the
duration of three machine cycles. It is possible to invert the device state.
Configuration log
Note
A configuration which uses inputs 2.Y1 or 2.Y2 cannot be operated in a single channel
AS-Interface safety monitor.
If the Inverted parameter is activated, the inverter icon precedes the icon for the monitor input
device in the configuration.
Notice
The use of a monitor input device for safe switching tasks is not permitted!
Example:
0018 INDEX: 32 = "Name"
0019 TYPE: 28 = monitor input
0020 ASSIGNED: channel one
0021 INPUT: 1.Y2 invert
8
9
0
1