Configuring the AS-Interface safety monitor
4.3 Creating and changing a configuration
ASIMON V3 - Configuration software for AS-Interface safety monitor
52 Programming and Operating Manual, Edition 09/2008, GWA 4NEB 333 1558 02 DS 02
Double channel dependent
Icon
Functional device Double channel dependent safety input
Parameter
Name: max. 29 ASCII characters plaintext
Address: AS-Interface bus address (1… 31)
Start-up test: with / without
Synchronisation time: 100ms … 30s in multiples of 100ms or (infinite)
Local acknowledgement: with / also after startup / without
Slave type: standard/A/B slave
Address: AS-Interface bus address of the local acknowledgement
(1 … 31)
Bit address: In-0 … In-3 or Out-0 … Out-3, inverted / not inverted
Input mask
Type Designation in the configuration log
21 double channel dependent safety input
Variants
Without startup test SUBTYPE: no startup test
With startup test SUBTYPE: startup test
Without local acknowledgement SUBTYPE: no local acknowledge
With local acknowledgement SUBTYPE: local acknowledge
With local acknowledgement
also after startup
SUBTYPE: local acknowledge always