Configuring the AS-Interface safety monitor
4.3 Creating and changing a configuration
ASIMON V3 - Configuration software for AS-Interface safety monitor
132 Programming and Operating Manual, Edition 09/2008, GWA 4NEB 333 1558 02 DS 02
4.3.8 Activating and deactivating devicesChanging the state of the devices
AS-Interface safety monitors starting with version 2.0 offer the possibility to activate and
deactivate devices. As a result, it is possible to configure all conceivable options in the safety-
relevant design of a machine. Through targeted deactivation of devices, the configuration can
be adapted to the actual situation.
Deactivating devices
When you select a device with the mouse and click the right mouse button, the following
pop-up menu opens:
Note
This functionality is only available in AS-Interface safety monitors starting with version 2.0.
Caution
Observe all safety regulations when you deactivate a device. This must only be performed by
an authorised safety technician.