Commissioning the AS-Interface safety monitor
5.8 Configuration documentation
ASIMON V3 - Configuration software for AS-Interface safety monitor
Programming and Operating Manual, Edition 09/2008, GWA 4NEB 333 1558 02 DS 02 155
Printing the configurationWith the Print -> Configuration as text … command in the File menu, you can also print out
the configuration currently present in ASIMON as a list.
Following is an example of such a configuration hardcopy.
Note
Printing the configuration using the Print command in the File menu does not replace the con-
figuration log. It serves only as a good documentation aid in the set program language.
- 1 -
AS-interface safety monitor configuration
Date: 22.02.2008 15:02:13
Configuration title: Configuration 1
Download time: 04.Januar 2007 . 14:51
Monitor address: 28 / 29 / 30 / 31
AS-interface diagnosis: all devices
Operating mode: two independent OSSDs
Diagnosis stop: -
Reset of error condition: -
[32]Emergency shutdown
Name: "NA 1"
Type: forced
Start-up test: No
Local acknowledgement: No
OSSD: 1 / 2
Address: 1
[33]Emergency shutdown
Name: "NA 3"
Type: forced
Start-up test: No
Local acknowledgement: No
OSSD: 1
Address: 2
[34]Emergency shutdown
Name: "NA 2"
Type: forced
Start-up test: No
Local acknowledgement: No
OSSD: 2
Address: 4
[35]AOPD
Name: "BWS 1"
Type: forced
Start-up test: No
Local acknowledgement: No
OSSD: 1 / 2
Address: 3
[36]Monitored start - standard slave
Name: "S 2"
OSSD: 2
Address: 10 In-1 not inverted
[37]Monitored start - standard slave
Name: "S 1"
OSSD: 1
Address: 10 In-0 not inverted
[38]Stop category 0
Name: "M 1"
OSSD: 1
[39]Stop category 0
Name: "M 2"
OSSD: 2