Configuring the AS-Interface safety monitor
4.3 Creating and changing a configuration
ASIMON V3 - Configuration software for AS-Interface safety monitor
Programming and Operating Manual, Edition 09/2008, GWA 4NEB 333 1558 02 DS 02 97
External device monitoring circuit with standard slave for dependent, second OSSD
Icon
Functional device External device monitoring circuit with standard slave for dependent,
second OSSD
Parameter
Name: max. 29 ASCII characters plaintext
Switching time: 10 … 1000ms, switching time of the contactor
Limited error lock: with / without
Slave type: standard/A/B slave
Address: AS-Interface bus ad dress (1 … 31)
Bit address: In-0 … In-3 or Out-0 … Out-3, inverted / not inverted
Input mask
Note
This EDM device can only be used in the 1st OSSD of a configuration with two dependent
output groups.
Type Designation in the configuration log
63 external device monitor channel two standard slave
Variants
Error lock SUBTYPE: none