First steps
3.2 Description of the user interface
ASIMON V3 - Configuration software for AS-Interface safety monitor
Programming and Operating Manual, Edition 09/2008, GWA 4NEB 333 1558 02 DS 02 31
• With the keyboard:
- with the <Tab> key: change window areas.
- with the arrow keys: select circuit, device or position.
- execute actions using the following keyboard commands:
<Ctrl> + <D> = Activate/Deactivate
<Ctrl> + <I> = Invert
<Delete> = Delete
<Ctrl> + <C> = Select
<Ctrl> + <V> = Paste
<Shift> + <Ctrl> + <V>= Move
<Ctrl> + <A> = Assign
<Ctrl> + <R> = Replace
In addition to the devices themselves, you can also change the connection lines of the devices
(and thus the device assignment).
Figure 3-15 Device assignment by creating/moving connection lines
Note
If a monitoring device from an OSSD is to be assigned to a link in a new (non-OSSD window),
the link must first be created. After creating the link, select the monitoring device in the OSSD
(<Ctrl> + <C>) and assign it to the logic device in the new window (click the logic device and
press <Ctrl> + <A>).
1 2 3
Click the output of a
device with the left
mouse button and
hold down.
Pull the connection line ("rubber band")
to the input on the desired device and
release the left mouse button.
Device is
assigned to
the link