5. Data - CSD/HSCSD

Note! Since the module does not support V42bis compression the following commands have not been implemented:

AT+DS

AT+DR

5.1 AT+CBST

Select Bearer Service Type

 

 

 

 

 

 

 

Description

Command

Possible Responses

 

 

 

 

 

 

Select bearer service

AT+CBST=[<speed>,

OK

 

type

[<name>,[<ce>]]]

ERROR

 

 

 

 

 

 

Show the current

AT+CBST?

+CBST:

 

setting

 

 

<speed>,<name>,

 

 

 

 

<ce>

 

 

 

• OK

 

 

 

• ERROR

 

Show if the command

AT+CBST=?

• +CBST: (list of supported

 

is supported

 

 

<speed>s,list of

 

 

 

 

supported <name>s, list

 

 

 

 

of supported <ce>s)

• OK

• ERROR

Selects the bearer service <name> with data rate <speed>, and the connection element <ce> to be used when data calls are originated. Values may also be used during mobile terminated data call setup, especially in the case of single numbering scheme calls.

Test command returns values supported by the TA as compound values.

<speed>

Description

 

 

0

Auto selection of baud rate

 

 

4

2400bps V.22bis

 

 

6

4800bps V.32

 

 

7

9600bps V.32

 

 

12

9600bps V.34

 

 

15

19200bps V.34

 

 

68

2400bps V.110 (ISDN)

 

 

70

4800bps V.110 (ISDN)

153

LZT 123 7263 R1C

Page 153
Image 153
Sony Ericsson GM47, GM48 manual Data CSD/HSCSD, Select Bearer Service Type, At+Cbst?, At+Cbst=?