2. SYSTEM CONNECTOR INTERFACE

The following timing diagram illustrates both power-up and power- down processes.

Module on

Module off

t1

t2

ON/OFF

tpwr

VIO

Module powered

Module power-up

Module power-down

Figure 2.2 ON/OFF timing and VIO performance

Times are defined as follows:

Time

Description

Min.

Typ.

Max. Units

 

 

 

 

 

t1

Turn-on pulse time

2

 

s

t2

tpwr

Turn-off pulse time

Hardware-reset pulse timea

Time for VIO and internal voltages to be established

1s

>10s

100

200

ms

a. Active only when a full system reset is required.

2.5.2 VIO - 2.75V Supply

VIO provides an output voltage derived from an internal 2.75V regulator. Its electrical characteristics are shown below.

Parameter

Min.

Typ.

Max.

Units

 

 

 

 

 

Output Voltage (Iload = 50mA)

2.70

2.75

2.85

V

Load current

 

 

75

mA

 

 

 

 

 

You can use this output for the following:

to indicate that the module is alive;

to power interface circuits, external to the module.