11. INPUT/OUTPUT

AT Command

Response

Comment

 

 

 

AT*E2IO=1,“DA1”,95

 

The TE is writing 95 decimal

 

 

value to hold a voltage of:

 

 

((2.75*0.9)/256)*95 = 0.918V

 

OK

The MS responds OK because

 

 

the operation has been

 

 

performed

 

 

 

Configuring an I/O:

AT Command

Response

Comment

 

 

 

AT*E2IO=2,“I1”,0

 

The TE is requesting to

or

 

configure IO1 as an input

AT*E2IO=2,“O1”,0

 

 

 

OK

The MS responds OK because

 

 

the operation has been

 

 

performed

 

 

 

AT*E2IO=2,“I4”,1

 

The TE is requesting to

or

 

configure IO4 as an output

AT*E2IO=2,“O4”,1

 

 

 

OK

The MS responds OK because

 

 

the operation has been

 

 

performed

 

 

 

Checking an I/O status:

AT Command

Response

Comment

 

 

 

AT*E2IO=3,“I1”

 

The TE is requesting to check

or

 

the configuration of the IO1

AT*E2IO=3,“O1”

 

signal

 

*E2IO:3,“I1”,0

The MS responds IO1 is

 

OK

configured as an input

 

or

 

 

*E2IO:3,“O1”,0

 

 

OK

 

 

 

 

AT*E2IO=3,“I4”

 

The TE is requesting to check

or

 

the configuration of the IO4

AT*E2IO=3,“O4”

 

signal

 

*E2IO:3,“I4”,1

The MS responds IO4 is

 

OK

configured as an output

 

or

 

 

*E2IO:3,“O4”,1

 

 

OK

 

 

 

 

195

LZT 123 7263 R1C

Page 195
Image 195