4Section 2.8 “How to Avoid Electrostatic Discharge” on page 69

Caution - Be sure that the AC power cord(s) is disconnected from the back of the system before performing this procedure. Attempting to replace the power distribution board while the AC power cord is plugged into a power source can result in serious personal injury.

5.4.2What to Do

1.Position the power distribution board in the chassis floor.

You may need to adjust the cable attached to the center AC power connector assembly so that it does not interfere with the positioning of the power distribution board.

2.Replace the seven Phillips screws that secure the board to the chassis.

3.Replace the AC power connector assembly (and the cable attached to it). Use a Phillips #2 screwdriver.

152 Sun Enterprise 220R Server Service Manual January 2000, Revision A