Parameter | Value |
|
|
Input |
|
Nominal Frequencies | 50 Hz or 60 Hz nominal |
Nominal Voltage Range | 100 to 240 VAC |
Maximum Current AC RMS | 6.3 A @ 100 VAC |
AC Operating Range | 90 to 264 Vrms, 47 to 63Hz |
Outputs |
|
5.1 VDC1 | 0.1 to 1 A |
+3.3 VDC2 | 3 to 50 A |
+5 VDC3 | 3 to 40 A |
+12 VDC | 0.5 to 5 A |
0 to 0.5 A | |
Maximum DC Power Output | 380 Watts |
Maximum AC Power Consumption | 610 Watts |
Maximum Heat Dissipation | 2080 BTUs/hr |
630 VA with 380 Watt load |
1.Standby output.
2.Combined output power of the +33 VDC and +5 VDC outputs must not exceed 320 Watts.
3.Combined output power of the +3.3 VDC and +5 VDC outputs must not exceed 320 Watts.
B.1.3 Environmental Specifications
The environmental requirements for the system are as follows.
Parameter | Value |
|
|
|
|
|
|
|
|
Operating |
|
|
|
|
Temperature | ˚ | ˚ | ˚ | ˚ |
| 5C to 35C (41F to | |||
Humidity | 20% to 80% RH, noncondensing; 27˚C max wet | |||
|
|
|
|
|
246 Sun Enterprise 220R Server Service Manual ♦ January 2000, Revision A