Pin

Mnemonic

Signal Name

Description

 

 

 

 

6

DSR

Data Set

Used by the DCE to indicate if it is ready to

 

 

Ready

operate. When DSR is ON, the DCE is

 

 

 

connected to the line and ready to exchange

 

 

 

further control signals to start data transfer.

7

Gnd

Signal

 

 

 

Ground

 

8

DCD

Data Carrier

Used by the DCE to indicate it is receiving a

 

 

Detect

suitable signal from the communications

 

 

 

channel.

9

 

Not

None.

 

 

connected

 

10

 

Not

None.

 

 

connected

 

11

 

Not

None.

 

 

connected

 

12

 

Not

None.

 

 

connected

 

13

 

Not

None.

 

 

connected

 

14

 

Not

None.

 

 

connected

 

15

TRXC

Transmit

Used by the DCE to provide timing

 

 

Clock

information to the DTE. The DTE provides

 

 

 

data on TXD in which the transition of the bit

 

 

 

corresponds to the rising edge of the clock.

16

 

Not

None.

 

 

Connected

 

17

RTXC

Receive

Used by the DCE to provide timing

 

 

Clock

information to the DTE. The falling edge of

 

 

 

the clock corresponds to the center of the

 

 

 

data bit received on RXD.

18

 

Not

None.

 

 

connected

 

19

 

Not

None.

 

 

connected

 

 

 

 

 

234 Sun Enterprise 220R Server Service Manual January 2000, Revision A

Page 234