7.6.11 NVRAM
The NVRAM diagnostic verifies the NVRAM operation by performing a write and
read to the NVRAM.
The following example shows the NVRAM diagnostic output message.
CODEEXAMPLE 7–4
Enter (0-11 tests, 12 -Quit, 13 -Menu) ===> 8
TEST=’nvram_test’
SUBTEST=’write/read_patterns’
SUBTEST=’write/read_inverted_patterns’
Enter (0-11 tests, 12 -Quit, 13 -Menu) ===>
7.6.12 Audio
The audio diagnostic is not included for this system.
7.6.13 SCSI
The SCSI diagnostic validates both the SCSI chip and the SCSI bus subsystem.
The following example shows the SCSI diagnostic output message.
CODEEXAMPLE 7–5
Enter (0-11 tests, 12 -Quit, 13 -Menu) ===> 10
TEST=’selftest’
Enter (0-12 tests, 13 -Quit, 14 -Menu) ===>
7.6.14 All Above
The all above diagnostic validates the system.
The following example shows the all above diagnostic output message.
Note - The all above diagnostic stalls if the tip line is installed on serial port A or
serial port B.
Diagnostics and Troubleshooting 203