7.3.2 What to Do
Ensure that the front panel keyswitch is in the Standby position.
Youcan initialize POST one of two ways:
By setting the diag-switch? to true and the diag-level to max or min,
followed by power cycling the system unit
By simultaneously pressing the keyboard Stop and D keys while power isapplied
to the system unit
Toset the diag-switch? to true and power cycle the system unit:
1. When the ok prompt is displayed, type the following command:
ok setenv diag-switch? true
2. At the Type-5 keyboard, power cycle the system by simultaneously pressing
the Shift key and the Power-on key After a few seconds press the Power-on
key again, or press the Power button on the system once.
Note - The keyswitch must be set to the Power-On/Off position.
The system runs the POST diagnostics. POST displays status and error messageson
the system console. For more information, see the “Results” section below.
Upon successful completion of POST,the system runs OBDiag. For more information
about OBDiag, see Section 7.5 “About OpenBoot Diagnostics (OBDiag)” on page 192
and Section 7.6 “How to Use OpenBoot Diagnostics (OBDiag)” on page 195.
7.3.3 Results
While POST is running, you can observe its progress and any error indications in the
following locations:
System console or through a tip connection
Front panel fault LEDs
Keyboard LEDs (if a keyboardis present)
Diagnostics and Troubleshooting 189