Toshiba Three-phase 200V class 0.1 to 2.2kW instruction manual Display of trip information

Models: Single-phase 100V class 0.1 to 0.75kW Three-phase 200V class 0.1 to 2.2kW Single-phase 200V class 0.2 to 2.2kW

1 144
Download 144 pages 31.84 Kb
Page 101
Image 101

E6581090

8.2Display of trip information

If the inverter trips, an error code is displayed to suggest the cause. In the status monitor mode, all trip records are retained.

Display of trip information

 

 

 

 

Error code

Communication No.

Description

 

 

 

PGTT (*)

0000

No error

 

 

 

QE

0001

Overcurrent during acceleration

 

 

 

QE

0002

Overcurrent during deceleration

 

 

 

QE

0003

Overcurrent during operation

 

 

 

QEN

0004

Load-side overcurrent during start-up

 

 

 

QEC

0005

Armature-side overcurrent during start-up

 

 

 

GRJ

0008

Input phase failure

 

 

 

GRJQ

0009

Output phase failure

 

 

 

QR

000A

Overvoltage during acceleration

 

 

 

QR

000B

Overvoltage during deceleration

 

 

 

QR

000C

Overvoltage during constant-speed operation

 

 

 

QN

000D

Inverter overload trip

 

 

 

QN

000E

Motor overload trip

 

 

 

QJ

0010

Overheat trip

 

8

 

G

0011

Emergency stop

 

 

GGR

0012

E2PROM fault 1

 

 

 

GGR

0013

E2PROM fault 2

 

 

 

GGR

0014

E2PROM fault 3

 

 

 

GTT

0015

Inverter RAM fault

 

 

 

GTT

0016

Inverter ROM fault

 

 

 

GTT

0017

CPU fault trip

 

 

 

GTT

0018

Communication error

 

 

 

GTT

001A

Current detector fault

 

 

 

WR

001E

Undervoltage trip

 

 

 

GH

0022

Ground fault

 

 

 

QER

0025

Overcurrent flowing in element during acceleration

 

 

 

QER

0026

Overcurrent flowing in element during deceleration

 

 

 

QER

0027

Overcurrent flowing in element during low-speed operation

 

 

 

G

0032

Trip caused by a break in an analog signal cable

 

 

 

G

0033

CPU communication error

 

 

 

G

0034

Excessive torque boosted

 

 

(Note) Past trip records (trip records retained or trips that occurred in the past) can be called up. (Refer to 8.1 "Status monitor mode" for the call-up procedure.)

(*)Strictly speaking, this code is not an error code; this code is displayed to show the absence of error when the past trip monitor mode is selected.

H-3

Page 101
Image 101
Toshiba Three-phase 200V class 0.1 to 2.2kW, Single-phase 200V class 0.2 to 2.2kW Display of trip information