Adjustment scale with meter adjustment HO parameter

Connect meters as shown below.

<Frequency meter>

Meter: frequency

+meter

FM/OUT (default setting)

VF-nC1

-

 

 

 

CC

 

 

The reading of the frequency

 

 

 

meter will fluctuate during

 

 

 

scale adjustment.

<Ammeter>

 

FM/OUT

 

VF-nC1

-

CC

 

Meter: ammeter

(HOUN: 1)

The reading of the frequency meter will fluctuate during scale adjustment.

Optional frequency meter: QS-60T

[Connected meter selection parameters]

Make the maximum ammeter scale at least 150 percent of the inverter's rated output current.

Title

Function

 

Adjustment range

Default setting

 

 

 

-1 : Open collector output

 

 

5

 

 

0

: Output frequency

 

 

 

 

1

: Output current

 

 

 

 

Meter selection

2

: Set frequency

0

 

 

HOUN

3 : For adjustment (current fixed at 100%)

 

 

 

 

4

: For adjustment (current fixed at 50%)

 

 

 

 

 

5

: For adjustment (output fixed at the max

 

 

 

 

 

 

frequency)

 

 

 

 

 

6

: For adjustment (gain display )

 

 

 

Resolution

All FM terminals have a maximum of 1/256

[Example of how to adjustment the FM terminal frequency meter] * Use the meter's adjustment screw to pre-adjust zero-point.

Key operated

LED display

 

 

 

 

Operation

 



Displays the operation frequency. (When standard monitor

 

display selection H is set to  [operation frequency])

 

 

 

MON

 

CWJ

The first basic parameter "CWJ" is displayed.

 

 

 

 

 

 

 

 

 

 

HO

Press either the key or the key to select "HO."

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the ENTER key to confirm your choice. A value

ENT

 



corresponding to the setting of HOUN (FM/OUT terminal

 

 

 

functions selection) is displayed.

 

 

 

Press the key or the key to adjust the meter. The

 

 

 

meter reading will change at this time but be careful

 

 

 

because there will be no change in the inverter's digital LED



(monitor) indication.

 

 

 

 

 

 

 

[Hint]

 

 

 

 

 

 

 

 

 

It's easier to make the

 

 

 

 

 

 

 

 

 

adjustment if you push and

 

 

 

 

 

 

 

 

 

hold for several seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENT

 

HO

The adjustment is complete. HO and the frequency are

 

displayed alternately.

 

 

 

The display returns to its original indications (displaying the

MON

MON



operation frequency). (When standard monitor display

 

 

 

selection H is set to  [operation frequency].)

Adjusting the meter in inverter stop state

If, when adjusting the meter for output current, there are large fluctuations in data during adjustment, making adjustment difficult, the meter can be adjusted in inverter stop state.

If HOUN is set to  “for adjustment (current fixed at 100%)”, the inverter puts out signals via the FM / OUT terminal, assuming that 100% of current (inverter’s rated current) is flowing. In this state, adjust the meter with the HO (Meter adjustment) parameter. (HOUN: 4, 5, 6, 7 can be adjusted in the same way.)

After meter adjustment is ended, set HOUN to  (output current).