Toshiba Three-phase 200V class 0.1 to 2.2kW instruction manual Protection functions

Models: Single-phase 100V class 0.1 to 0.75kW Three-phase 200V class 0.1 to 2.2kW Single-phase 200V class 0.2 to 2.2kW

1 144
Download 144 pages 31.84 Kb
Page 86
Image 86

E6581090

2)Changing the acceleration/deceleration time by adjusting the contact input signal

Changing the acceleration/deceleration time, using external terminals –

Output frequency [Hz]

0

Time (sec)

 

 

 

 

ON

R(AD2)-CC

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

Accelerated at the gradient of Decelerated at the gradient

6

 

time set with CEE

of time set with H

Accelerated at the gradient of Decelerated at the gradient

time set with H

of time set with FGE

This switching is done when acceleration/deceleration 2 (AD2) is assigned to the R terminal (when H (input terminal selection 2) is set to 5 (acceleration/deceleration 2)), using the multi- function programmable input terminal function.

In this case, set EOQF to 0 (terminal block).

No signal for switching to acceleration/deceleration 2 is set by default. If necessary, assign function 5 (AD2) to an unassigned terminal, using the input terminal selection function.

6.14Protection functions

6.14.1Current stall setting

H

:Stall prevention level

Function

If a current exceeding the level specified with H, the stall prevention function is activated to decrease the output frequency.

When specifying a value larger than 100 (%), set also the VMT parameter (motor electronic thermal protection level) properly.

Parameter setting

Title

Function

Adjustment range

Default setting

H

Stall prevention level

30199 (%)

150

200: Invalid

 

 

 

[Message displayed along with an QE alarm]

If an QE alarm goes off (if a current exceeding the stall prevention level), the output frequency displayed will change and the “E” on the left of it will blink.

Example of display :

E

F-21

Page 86
Image 86
Toshiba Three-phase 200V class 0.1 to 2.2kW Protection functions, Current stall setting  Stall prevention level