Table of input terminal functions 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

Code

Function

 

Action

 

 

 

 

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

29

R+SS4

Combination of reverse run and preset

ON

: Simultaneous input of R and SS4

 

 

 

speed command 4

 

commands

 

 

 

 

 

 

 

 

 

 

 

30

F+SS1+AD2

Combination of forward run, preset

ON

: Simultaneous input of F, SS1 and

 

 

 

 

speed command 1 and

 

 

 

 

AD2 commands

 

 

 

 

 

 

acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

 

 

 

 

31

R+SS1+AD2

Combination of reverse run, preset

ON

: Simultaneous input of R, SS1 and

 

 

 

 

speed command 1 and

 

 

 

 

AD2 commands

 

 

 

 

 

 

acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combination of forward run, preset

ON

: Simultaneous input of F, SS2 and

 

 

 

 

32

F+SS2+AD2

speed command 2 and

 

 

 

 

AD2 commands

 

 

 

 

 

 

acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

 

 

 

 

33

R+SS2+AD2

Combination of reverse run, preset

ON

: Simultaneous input of R, SS2 and

 

 

 

 

speed command 2 and

 

 

 

 

AD2 commands

 

 

 

 

 

 

acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

 

 

 

 

34

F+SS3+AD2

Combination of forward run, preset

ON

: Simultaneous input of F, SS3 and

 

 

 

 

speed command 3 and

 

 

 

 

AD2 commands

 

 

 

 

 

 

acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combination of reverse run, preset

ON

: Simultaneous input of R, SS3 and

 

 

 

 

35

R+SS3+AD2

speed command 3 and

 

 

 

 

AD2 commands

 

 

 

 

 

 

acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

 

 

 

 

36

F+SS4+AD2

Combination of forward run, preset

ON

: Simultaneous input of F, SS4 and

 

 

 

 

speed command 4 and

 

 

 

 

AD2 commands

 

 

 

 

 

 

acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

 

 

 

 

37

R+SS4+AD2

Combination of reverse run, preset

ON

: Simultaneous input of R, SS4 and

 

 

 

 

speed command 4 and

 

 

 

 

AD2 commands

 

 

 

 

 

 

acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enabled if  = 4 (selectable

 

11

 

 

 

 

 

 

 

 

 

 

between terminal board and operation

 

 

38

FCHG

Frequency command forced switching

panel/internal potentiometer)

 

 

 

 

 

 

 

ON

: VI terminal

 

 

 

 

 

 

 

OFF : Internal potentiometer

 

 

 

 

 

 

 

ON

: No.2 thermal (:, ,

 

 

 

 

39

THR2

No.2 thermal switching

 

, , )

 

 

 

OFF : No.1 thermal (: Setting, ,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

, , )

 

 

 

 

40

 

 

ON

: No.2 motor (:0, ,

 

 

 

 

 

 

 

 

, , , ,

 

 

 

 

 

MCHG

No.2 motor switching

 

)

 

 

 

 

 

OFF : No.1 motor (Pt: Setting, ,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

, , , ,

 

 

*1

 

 

 

 

)

 

 

 

 

Operation holding

ON

: F (forward run) / R (reverse run)

 

 

 

 

49

HD

 

held, 3-wire operation

 

 

 

(Stop of 3-wire operation)

 

 

 

 

 

 

 

OFF : Slowdown stop

 

 

 

 

 

 

 

 

 

 

 

54

FreeRun

Standby (inversion)

ON

: Free run

 

 

 

OFF : Standby

 

 

 

 

 

 

 

 

 

 

 

55

RSTN

Reset signal (inversion)

OFF to ON: Trip reset

 

 

 

 

56

F+ST

Combination of forward run and standby

ON

: Simultaneous input of F and ST

 

 

 

commands

 

commands

 

 

 

 

 

 

 

 

 

 

 

57

R+ST

Combination of reverse run and standby

ON

: Simultaneous input of R and ST

 

 

 

commands

 

commands

 

 

 

 

 

 

 

 

*1 This function is effective after software version V110.