6.15.3 Changing the standard monitoring item
H
• Function
:Selection of monitor display selection
This parameter is used to change the item displayed when the power is turned on.
☆When the power is turned on, the operation frequency is displayed by default like this: “” or “QHH”. You can change this default monitoring item, using H. In that case, however, no prefixes (such as V and E) will be displayed.
|
|
| ■Parameter settings |
|
| ||
|
|
|
| Title | Function | Adjustment range | Default setting |
|
|
|
|
| Selection of | 0: Operation frequency (Hz/free unit) | 0 |
|
|
|
| H | monitor display | 1: Frequency command (Hz/free unit) | |
|
|
|
|
| selection | 2: Output current (%/A) |
|
|
|
|
|
|
|
|
|
6 | 6.16 |
| Communication function (common serial) |
| |||
|
|
|
|
|
|
|
|
H : Communication baud rate
H : Parity
H : Inverter number
H : Communication error trip time
For details, refer to the Communications Equipment User’s Manual.
• Function
The
binary codes)
☆The following unit and cables are optionally available for common serial communications.
•RS232C conversion unit (Model: RS2001Z)
Communications cable (Model: CAB0011 (1m), CAB0013 (3m), CAB0015 (5m))
•Cable with a
•RS485C conversion unit with a terminal board (Model: RS4001Z, RS4002Z)
•Communications cable (Model: CAB0011 (1m), CAB0013 (3m), CAB0015 (5m))
Note: Use a cable 5 m or less in length to connect an inverter and an optional common serial unit.