6.10.2 Regenerative power ride-through control/slowdown stop control



: Regenerative power ride-through control

Function

Regenerative power ride-through control :

Function of letting the motor continue to run using its regenerative energy in the event of a momentary power failure. (Enabled if  is set to 1 (enabled))

Slowdown stop control:

Function of quickly stopping the motor in case a momentary power failure occurs during operation. Motor regenerative energy is used to forcibly bring the motor to a stop. (Enabled if  is set to 2 (slowdown stop))

If the motor is stopped forcibly, it remains at a standstill until the operation command is cancelled temporarily or the power is turned off.

[Parameter setting]

 

 

 

 

 

 

Title

Function

Adjustment range

Default setting

 

 

 

 

Regenerative power

0: Disabled,

0

 

6

 



1: Enabled,

 

 

ride-through control

 

 

 

2: Slowdown stop

 

 

 

 

 

 

 

 

 

Note: Even if this parameter is set to 1 (enabled), the motor may coast to a stop under some load conditions. In that case, use this function along with the auto-restart function.

[When the power is interrupted]

Input voltage

Motor speed

The time for which the operation of the motor is continued depends

on the machine’s inertia or load conditions. Before using this

function, therefore, perform a test to determine the inertial and load conditions.

The use of the retry function along with this function allows the

motor to be restarted automatically without being brought to a stop.

Regenerative power ride-through control is performed for about

Approx. 10ms (if  is set to 1). 100ms

[When momentary power failure occurs] Input voltage

Motor speed

Less than 100 ms

6.10.3 Retry function



: Retry selection (Selecting the number of times)

Caution

Stand clear of motors and machines when the retry function is activated.

When the retry function is enabled, the motor and machine in alarm-stop status will restart suddenly after the specified time, and could cause injury.

 

Mandatory

To prevent accidents, attach words of caution saying that the retry function is enabled to the

 

 

inverter, motor and machine.

 

 

 

Function

 

 

 

 

 

This parameter resets the inverter automatically when the inverter gives an alarm. During the

 

 

retry process, the motor search faction is activated automatically, if necessary for restarting the

 

 

motor smoothly.

 

 

 

 

[Parameter setting]

 

 

 

 

Title

Function

Adjustment range

Default setting

 

 



Retry selection (number of

0: Disabled,

0

 

 

times)

1~10: 1~10 times

 

 

 

 

 

 

 

 

 

 

 

 

 