Toshiba Three-phase 200V class 0.1 to 2.2kW Extended parameters, Input/output parameters, Low

Models: Single-phase 100V class 0.1 to 0.75kW Three-phase 200V class 0.1 to 2.2kW Single-phase 200V class 0.2 to 2.2kW

1 144
Download 144 pages 31.84 Kb
Page 116
Image 116

E6581090

11.3Extended parameters

Input/output parameters

 

Communication

 

 

Minimum setting

 

Default

User

 

 

 

Title

Function

Unit

unit Panel/

Adjustment range

Reference

 

 

No.

setting

setting

 

 

 

 

 

 

Communication

 

 

 

 

 

 



0100

Low speed signal

Hz

0.1/0.01

0.6-

0.6

 

6.1.1

 

 

 

 

output frequency

 

 

 

 

 

 

 

 



0101

Speed-reach setting

Hz

0.1/0.01

0.0-

0.0

 

6.1.2

 

 

 

 

frequency

 

 

 

 

 

 

 

 



0109

Analog input/logic

-

-

0:Voltage signal input

0

 

6.2.1

 

 

 

 

input function

 

 

(0-5 or 10V)

 

 

 

 

 

 

 

selection (VI/S3)

 

 

1:Current signal input

 

 

 

 

 

 

 

 

 

 

(4-20mA)

 

 

 

 

 

 

 

 

 

 

2:Contact input

 

 

 

 

 



0110

Always active

-

-

0~40, 49, 54~61

1

 

6.2.2

 

 

 

 

function selection

 

 

 

(ST)

 

 

 

 



0111

Input terminal

-

-

0~40, 49, 54~61

2

 

6.2.3

 

 

 

 

selection 1 (F)

 

 

 

(F)

 

 

 

 



0112

Input terminal

-

-

0~40, 49, 54~61

3

 

6.2.3

 

 

 

 

selection 2 (R)

 

 

 

(R)

 

 

 

 



0113

Input terminal

-

-

0~40, 49, 54~61

6

 

6.2.3

 

 

 

 

selection 3 (S1)

 

 

 

(SS1)

 

 

 

 



0114

Input terminal

-

-

0~40, 49, 54~61

7

 

6.2.3

 

 

 

 

selection 4 (S2)

 

 

 

(SS2)

 

 

 

 



0115

Input terminal

-

-

5-17

8

 

6.2.3

 

 

 

 

selection 5 (VI/S3)*5

 

 

 

(SS3)

 

 

 

 



0127

Sink/Source selection

-

-

0: Sink 100: Source

*2

 

6.2.5

 

 

 

 

 

 

 

1-99,101-200:

 

 

 

 

 

 

 

 

 

 

Disabled

 

 

 

 

 



0130

Output terminal

-

-

0-13

4

 

6.2.6

 

 

 

11

 

 

selection 1

 

 

 

(LOW)

 

 

 

 

 

(FM/OUT)*6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



0132

Output terminal

-

-

0-13

10

 

6.2.6

 

 

 

 

selection 3 (FL)

 

 

 

(FL)

 

 

 

 



0170

Base frequency 2

Hz

0.1/0.01

25-200

*2

 

6.3.1

 

 



0171

Base frequency

V

1/1

50-500

*2

 

6.3.1

 

 

 

 

voltage 2

 

 

 

 

 

 

 

 



0172

Torque boost 2

%

0.1/0.1

0.0-30.0

*3

 

6.3.1

 

 



0173

Motor thermal

%

1/1

30-100

100

 

6.3.1

 

 

 

 

protection level 2

 

 

 

 

 

 

 

 

*2: The value is changed according to the set-up parameter condition. (VFNC1 (S)-□□□□P-W type)

FH:80, UL80, VL:60, F127:0, F170:60, F171:200, F204:80, F409:200, F417:1710 for VFNC1 (S)-□□□

Ptype.

*3: Parameter values vary depending on the capacity. Refer to page K-8.

*5: This function is enabled if  is set at 2 (logic input).

*6: This function is enabled if  (open collector output) is set at 1.

K-3

Page 116
Image 116
Toshiba Three-phase 200V class 0.1 to 2.2kW instruction manual Extended parameters, Input/output parameters, Low