E6581090

Note: The self-up (self-lifting) terminals of VFNC1 are constructed with plastic body and screws, therefore please take following precautions.

 

Do not unscrew the power terminals to UP position frequently. (Less than 5 times is

 

 

recommended)

 

 

Do not press the screw when unscrew the main terminals.

 

 

1

 

Do not unscrew quickly like using an Electric screw driver.

 

Do not pull the power wire during unscrewing the power terminals to UP position.

 

Do not unscrew the power terminal to UP position with over torque.

 

 

Do not make any deformation of the cover when unscrewing the power terminals.

 

1.3.2

Main circuit and control circuit terminal blocks

 

 

1) Main circuit terminal block

When using a crimp terminal, cover its caulked part with a tube or use an insulated terminal.

Screw size

tightening torque

M3 screw

0.8N

m

M3.5 screw

1.0N

m

VFNC1-2001P2007P

[Main circuit input terminals]

[Main circuit output terminals]

A-5

Page 15
Image 15
Toshiba Single-phase 200V class 0.2 to 2.2kW, Single-phase 100V class 0.1 to 0.75kW instruction manual VFNC1-2001P~2007P