Do not install in any location of high temperature, high humidity, moisture condensation and freezing and avoid locations where there is exposure to water and/or where there may be large amounts

1of dust, metallic fragments and oilmist.

Do not install in any location where corrosive gases or grinding fluids are present.

Operate in areas where ambient temperature ranges from -10°C to 50°C. However, when installing the inverter where the ambient temperature will rise above 40°C, detach the caution label on the top surface.

5cm

5cm

5cm

Measurement position

Measurement position

Note: The inverter is a heat-emitting body. Make sure to provide proper space and ventilation

when installing in the cabinet. When installing the inverter in a cabinet, you are recommended to detach the caution label even if the temperature in the cabinet is below 40°C.

Do not install in any location that is subject to large amounts of vibration.

If the VF-nC1 Inverter is installed near any of the equipment listed below, provide measures to insure against errors in operation.

Solenoids:

Attach surge suppressor on coil.

Brakes:

Attach surge suppressor on coil.

Magnetic contactors: Attach surge suppressor on coil.

Fluorescent lights:

Attach surge suppressor on coil.

Resistors:

Place far away from VF-nC1

 

Inverter.

Resistor

A-14