supplyPower Rating

Item

Input voltage

Applicable motor (kW)

Type

Form

Capacity (kVA) Note 1)

Rated output current (A)

Note 2)

Rated output voltage

Note 3)

Overload current rating

Voltage-frequency

Allowable fluctuation

Ampere Interrupt

Capacity (A) AIC

Protective method

Cooling method

Color

Charge lamp

Built-in filter

 

 

 

 

 

 

E6581090

 

 

Specification

 

 

 

 

1-phase 100V

 

 

0.1

0.2

0.4

 

0.75

1.5

2.2

 

 

 

VFNC1S

 

 

1001P

1002P

1004P

 

1007P

-

-

0.3

0.6

1.0

 

1.6

-

-

0.7

1.4

2.4

 

4.0

-

-

 

 

 

 

 

 

 

3-phase 200V to 230V

60seconds at 150%, (50%-reduction value) 1-phase 100V to 115V - 50/60Hz

Voltage +10%, -15% Note 4), frequency ±5%

1000

1000

1000

 

1000

-

-

 

 

IP20 Enclosed type (JEM 1030)

 

 

 

Self-cooling

 

 

Forced

-

-

 

 

 

air-cooled

 

 

Munsel

5Y8/0.5

 

 

 

LED indicating the charge status of the capacitor in the main circuit

 

 

 

 

-

 

 

 

 

 

Item

 

 

 

Specification

 

 

 

 

 

Input voltage

 

 

1-phase 200V (built-in EM1 noise filter)

 

 

 

 

 

Applicable motor (kW)

0.1

0.2

 

0.4

 

0.75

 

1.5

2.2

 

 

 

Type

 

 

 

VFNC1S

 

 

 

 

 

 

 

Form

-

2002PL

 

2004PL

 

2007PL

 

2015PL

2022PL

 

 

Rating

Capacity (kVA) Note 1)

-

0.5

 

0.9

 

1.6

 

2.9

4.1

 

 

Note 2)

 

 

 

 

 

 

 

 

 

 

 

 

Rated output current (A)

-

1.2

 

2.3

 

4.0

 

7.5

10.7

 

 

 

 

 

 

 

 

 

 

Rated output voltage

 

 

 

3-phase 200V to 240V

 

 

 

 

 

Note 3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overload current rating

 

 

60 seconds at 150%, (50%-reduction value)

 

 

 

 

Power supply

Voltage-frequency

 

 

 

1-phase 200V to 240V - 50/60Hz

 

 

 

 

Allowable fluctuation

 

Voltage +10%, -15% Note 4), frequency ±5%

 

 

 

Ampere Interrupt

-

1000

 

1000

 

1000

 

5000

5000

 

 

 

Capacity (A) AIC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

Protective method

 

 

 

IP20 Enclosed

type (JEM 1030)

 

 

 

 

 

Cooling method

-

 

 

Self-cooling

 

 

Forced air-cooled

 

 

 

 

 

 

 

 

 

 

Color

 

 

 

Munsel 5Y8/0.5

 

 

 

 

 

 

Charge lamp

 

 

 

None

 

 

 

 

 

 

 

Built-in filter

 

 

 

EMC noise filter (Class B)

 

 

Note)

1.Capacity is calculated at 220V for the 200V models.

2.Indicates rated output current setting when the PWM carrier frequency (parameter H) is 4kHz or less.

If the PWM carrier frequency setting is fixed above 4 kHz, the rated current needs to be reduced. If the PWM carrier frequency is set above 4 kHz, it could fall automatically if an over-current flaws during acceleration or for any other reason, depending on the amount of current that flows.

The default setting of the PWN carrier frequency is 12kHz.

3.Maximum output voltage is the same as the input voltage.

With regard to 100V models, the output voltage may decrease about 10 to 20 % if motor load is applied. When operating VFNC1 in conjunction with general purpose motor (200V), it is necessary to reduce the motor load.

4.±10% when the inverter is used continuously (load of 100%).