Xerox 180 EPS Clearing a misfeed feeder tray fault, Troubleshooting, 21Press area 20 green lever

Models: 180 EPS 100

1 158
Download 158 pages 14.95 Kb
Page 133
Image 133
Figure 5-21 Press area 20 green lever

Troubleshooting

Figure 5-21 Press area 20 green lever

6.Remove any paper from the exposed area.

7.Press the green lever down and to the left until the latch catches.

8.Close the bypass transport module door.

Clearing a misfeed (feeder tray fault)

1.If the Ready to Open indicator is not lit, press the Tray Unlock button located on the feeder tray control panel.

Figure 5-22 If necessary, press Tray Unlock button

2.When the Ready to Open indicator lights, open the feeder tray. Pull the tray all the way out for best results.