Data Connections

Serial Data Port

RS-232 Interconnections Using a DB-25 Cable

To connect the printer’s RS-232 DB-9 interface to a DB-25 connector, an interface adapter is required (Zebra part number 33138). A generic DB-25 adapter may also be used, however, the +5 VDC signal source would not be passed through. Figure 46 shows the connections required for the DB-9 to DB-25 interface.

Note • Use a a null modem (crossover) cable to connect the printer to a computer or any other DTE devices.

Figure 46 • DB-9 to DB-25 Internal Connections

Male DB-9 Adapter

Female DB-25 Adapter

Connector

Connector

(plugs into printer)

(plugs into cable)

2

RXD

FG

1

 

 

3

TXD

TXD

2

 

 

4

DTR

RXD

3

 

 

5

SG

RTS

4

 

6

DSR

CTS

5

 

 

DSR

 

 

RTS

6

7

 

SG

 

 

7

 

CTS

 

8

+5 VDC

 

 

9

 

+5 VDC

SIGNAL

 

 

9

 

 

SIGNAL

DTR 20

 

Note • Pin 1 of DB-9 connector is unused and unterminated.