Configuration

Configuration and Calibration LCD Displays

Table 9 • Printer Parameters and Other LCD Displays (Sheet 13 of 15)

Parameter

Action/Explanation

 

 

B A C K F E E D

Backfeed Sequence

 

 

This parameter establishes when and how much label backfeed occurs after a label is

 

 

removed or cut in the peel-off or cutter modes. It has no effect in rewind or tear-off

 

 

modes. This parameter setting can be superseded by the ~JS instruction when

 

 

received as part of a label format (see the ZPL II Programming Guide Volume I).

 

 

The difference between the value entered and 100% establishes how much backfeed

 

 

occurs before the next label is printed. For example, a value of 40 means that 40% of

 

 

the backfeed takes place after the label is removed or cut. The remaining 60% takes

 

 

place before the next label is printed. A value of “before” means that all backfeed takes

 

 

place before the next label is printed.

 

 

Default: Default (90%)

 

 

Selections: Default, after, before, 10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, off

 

 

1.

Press SELECT to select the parameter.

 

 

2.

Press PLUS (+) or MINUS () to display other choices.

 

 

3.

Press SELECT to accept any changes and deselect the parameter.

 

 

 

LABEL

TOP

Adjusting Label Top Position

 

 

The label top position adjusts the print position vertically on the label. Positive numbers

 

 

adjust the label top position further down the label (away from the printhead); negative

 

 

numbers adjust the position up the label (toward the printhead).

 

 

Default: +0

 

 

Range: –120 to +120 dot rows

 

 

1.

Press SELECT to select the parameter.

 

 

2.

Press PLUS (+) to increase the value. The displayed value represents dots.

 

 

3.

Press MINUS () to decrease the value.

 

 

4.

Press SELECT to accept any changes and deselect the parameter.

 

 

 

LEFT

POSITION

Adjusting Left Position

 

 

This parameter establishes how far from the left edge of a label the format begins to

print by adjusting horizontal positioning on the label. Positive numbers adjust the printing to the left by the number of dots selected; negative numbers shift printing to the right.

Default: 0000

Range: –9999 to +9999

1.Press SELECT to select the parameter.

2.Press MINUS () to move to the next position.

3.Press PLUS (+) to change between +/– or to increase the value of the digit. The displayed value represents dots. For a negative value, enter the value before changing to the minus sign.

4.Press SELECT to accept any changes and deselect the parameter.

13163L Rev. 3 5/20/2004

Z4Mplus/Z6Mplus User Guide

69

Page 87
Image 87