Data Connections

Serial Data Port

RS-422/RS-485 Interconnections

Note • A jumper on the computer’s main logic board needs to be installed on JP1, Pins 2 and 3, for the RS-422/RS-485 interface adapter to function properly.

To connect the printer’s RS-232 DB-9 interface to a host computer through an RS-422 or an RS-485 interface, an interface adapter is required (Zebra part number 33130). Figure 47 shows the required cable wiring for interconnecting to the interface adapter’s DB-25 female connector.

Figure 47 • RS-422 and RS-485 Adapter Internal Connections

DB-25P

Connector

to Printer

Shield1

Signal Ground

11

 

Data Input A (–)

13

 

Data Output A (–)

14

 

Data Input B (+)

16

 

Data Output B (+) 19

106

Z4Mplus/Z6Mplus User Guide

13163L Rev. 3 5/20/2004