Routine Care and Adjustments

Position the Label Sensor

Position the Label Sensor

There are two media sensors in this printer: reflective and transmissive.

Adjust the Reflective Sensor

The reflective sensor detects the start-of-label indicator (the notch, hole, black mark, or gap between die-cut labels).

The reflective sensor must be positioned:

directly under the notch, hole, or black mark

anywhere along the width of the media if there is a gap between labels

The glow of the red light through the media may help you accurately position the reflective sensor.

Note • If you are using continuous media, position the reflective sensor anywhere under the media to detect an out-of-paper condition. The reflective sensor is compatible with most types of media. If you have difficulties with calibration, use the transmissive sensor. See Select the Transmissive Sensor on page 86.

Figure 38 • Adjusting the Reflective Sensor

1

2

3

4

1Printhead Assembly

2Reflective Sensor

3Adjustment Lever

4Printhead Open Lever

84

Z4Mplus/Z6Mplus User Guide