Zebra Technologies Z6Mplus manual Calibration Problems and Solutions

Models: Z6Mplus

1 142
Download 142 pages 63.75 Kb
Page 110
Image 110

Troubleshooting

Calibration Problems

Calibration Problems

Table 14 • Calibration Problems and Solutions

Problem

Recommended Solution

 

 

Loss of printing registration on

Ensure that the media guides are properly positioned.

labels.Excessive vertical drift in top-of-form

 

Set the printer for the correct media type. See MEDIA TYPE

registration.

on page 58.

 

 

 

 

Adjust the reflective sensor position. See Adjust the Reflective

 

Sensor on page 84.

 

 

 

Via the front panel, locate the SENSOR SELECT menu item

 

(see SENSOR SELECT on page 59) and manually select the

 

correct sensing method.

 

 

 

Reload the media. Check the reflective sensor position (see

 

Adjust the Reflective Sensor on page 84).

 

 

 

Clean the platen roller according to the instructions in Clean

 

the Printhead and Platen Roller on page 77.

 

 

Auto Calibrate failed.

Perform a manual calibration (see Media and Ribbon Sensor

 

Calibration (Manual Calibration) on page 63).

 

 

 

Reload the media and ensure that the reflective sensor is

 

properly positioned (see Adjust the Reflective Sensor

 

on page 84).

 

 

92

Z4Mplus/Z6Mplus User Guide

13163L Rev. 3 5/20/2004

Page 110
Image 110
Zebra Technologies Z6Mplus manual Calibration Problems and Solutions