Level Trace

Use this function to measure and display the AC impedance of an inactive pair as a function of frequency. This test can be used to analyze a pair for loading and bridge tap problems. The result is displayed on a graph with relative impedance level displayed on the y-axis (in dB) and the frequency on the x-axis. Attach the red and black test clips to the pair to be analyzed.

A normal, unloaded line would appear as a slowly decreasing line. Bulges or dips may indicate the presence of load coils.

Use the [Right] and [Left] keys to move the cursor across the graph. As the cursor is moved, a readout of the signal level and frequency will be displayed beneath the graph. A value of -3.53 dB corresponds to an impedance of 600 ohms at that frequency. 0 dB indicates a short-circuit and a large negative value corresponds to an open circuit. If part of the graph is off of the screen (out of view), use the [Down] key to reduce the gain. Use the [Up] key to increase the gain. Press the [Enter] key to repeat the test or the [Return] key to return to the dB menu.