Check RFL performance: To verify RFL, connect the red test lead to “R,” the black test lead to the “B,” the green lead to “G,” and the yellow lead to “Y.”
Press the [RFL] key on the 965DSP. Press the [SETUP] key, enter 70° F (21° C) for temperature. Press the [ENTER] key to accept. Select Separate Pair hookup, then continue. You should see the following readings for different wire gauges (US and Canada).
AWG | DTS | DTF | DSTF | ||||
|
|
|
|
|
|
| |
| min | max | min | max | min | max | |
| (ft/m) | (ft/m) | (ft/m) | (ft/m) | (ft/m) | (ft/m) | |
|
|
|
|
|
|
| |
19 | 11910 | 12290 | 1170 | 1230 | 10730 | 11070 | |
(3630) | (3747) | (357) | (375) | (3271) | (3375) | ||
| |||||||
|
|
|
|
|
|
| |
22 | 5986 | 6171 | 592 | 613 | 5393 | 5559 | |
(1825) | (1881) | (180) | (187) | (1644) | (1695) | ||
| |||||||
|
|
|
|
|
|
| |
24 | 3755 | 3871 | 371 | 385 | 3383 | 3488 | |
(1145) | (1180) | (109) | (117) | (1031) | (1063) | ||
| |||||||
|
|
|
|
|
|
| |
25 | 2970 | 3063 | 293 | 305 | 2676 | 2759 | |
(905) | (934) | (89) | (93) | (816) | (841) | ||
| |||||||
|
|
|
|
|
|
| |
26 | 2347 | 2420 | 232 | 240 | 2114 | 2180 | |
(716) | (738) | (71) | (73) | (645) | (665) | ||
| |||||||
|
|
|
|
|
|
| |
28 | 1479 | 1526 | 146 | 152 | 1332 | 1375 | |
(451) | (465) | (44) | (46) | (406) | (419) | ||
| |||||||
|
|
|
|
|
|
| |
Ohms | 99.3 | 102.5 | 9.8 | 10.2 | 89.5 | 92.3 | |
|
|
|
|
|
|
|