Check RFL performance: To verify RFL, connect the red test lead to “R,” the black test lead to the “B,” the green lead to “G,” and the yellow lead to “Y.”

Press the [RFL] key on the 965DSP. Press the [SETUP] key, enter 70° F (21° C) for temperature. Press the [ENTER] key to accept. Select Separate Pair hookup, then continue. You should see the following readings for different wire gauges (US and Canada).

AWG

DTS

DTF

DSTF

 

 

 

 

 

 

 

 

min

max

min

max

min

max

 

(ft/m)

(ft/m)

(ft/m)

(ft/m)

(ft/m)

(ft/m)

 

 

 

 

 

 

 

19

11910

12290

1170

1230

10730

11070

(3630)

(3747)

(357)

(375)

(3271)

(3375)

 

 

 

 

 

 

 

 

22

5986

6171

592

613

5393

5559

(1825)

(1881)

(180)

(187)

(1644)

(1695)

 

 

 

 

 

 

 

 

24

3755

3871

371

385

3383

3488

(1145)

(1180)

(109)

(117)

(1031)

(1063)

 

 

 

 

 

 

 

 

25

2970

3063

293

305

2676

2759

(905)

(934)

(89)

(93)

(816)

(841)

 

 

 

 

 

 

 

 

26

2347

2420

232

240

2114

2180

(716)

(738)

(71)

(73)

(645)

(665)

 

 

 

 

 

 

 

 

28

1479

1526

146

152

1332

1375

(451)

(465)

(44)

(46)

(406)

(419)

 

 

 

 

 

 

 

 

Ohms

99.3

102.5

9.8

10.2

89.5

92.3

 

 

 

 

 

 

 

145

Page 145
Image 145
3M 965DPS instruction manual AWG DTS DTF Dstf