SmartStrap™ Connection
The CTC Smart Strap™ Model C1100 supports Inactive Pair testing only and requires a separate, good control pair. A Wideband Module Model C1110W is required for Wideband Autotest. At the far end of the cable, connect the Control Pair (Pair
0)T and R terminals to the separate control pair in the cable. Connect the test pair tip conductor to the T terminal of Pair 1 (or higher) on the Smart Strap module and the test pair ring conductor to the R terminal of the same pair. Connect the Ground terminal to ground. Turn on the Smart Strap. Refer to the CTC Smart Strap™ Operator’s Manual for more information.
Dead Pair Test
|
| SmartStrap | ||
Black Lead |
|
| C1100 | |
| T | 3 | Test Pair | |
Red Lead |
| |||
|
| R |
|
|
|
| T | 2 | Test Good Pair |
|
| |||
|
| |||
|
| R |
|
|
|
|
|
| |
|
| T | 1 | Good Pair |
|
| |||
|
| |||
|
| R |
|
|
Blue Lead |
| T | 0 | Control Pair |
Yellow Lead |
| |||
|
| R |
|
|
|
|
|
|
Green Lead | Ground |
|
117