SmartStrap™ Connection

The CTC Smart Strap™ Model C1100 supports Inactive Pair testing only and requires a separate, good control pair. A Wideband Module Model C1110W is required for Wideband Autotest. At the far end of the cable, connect the Control Pair (Pair

0)T and R terminals to the separate control pair in the cable. Connect the test pair tip conductor to the T terminal of Pair 1 (or higher) on the Smart Strap module and the test pair ring conductor to the R terminal of the same pair. Connect the Ground terminal to ground. Turn on the Smart Strap. Refer to the CTC Smart Strap™ Operator’s Manual for more information.