SmartStrap™ Connection

The CTC Smart StrapModel C1100 supports Inactive Pair testing only and requires a separate, good control pair. A Wideband Module Model C1110W is required for Wideband Autotest. At the far end of the cable, connect the Control Pair (Pair

0)T and R terminals to the separate control pair in the cable. Connect the test pair tip conductor to the T terminal of Pair 1 (or higher) on the Smart Strap module and the test pair ring conductor to the R terminal of the same pair. Connect the Ground terminal to ground. Turn on the Smart Strap. Refer to the CTC Smart StrapOperator’s Manual for more information.

Dead Pair Test

 

 

SmartStrap

Black Lead

 

 

C1100

 

T

3

Test Pair

Red Lead

 

 

 

R

 

 

 

 

T

2

Test Good Pair

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

T

1

Good Pair

 

 

 

 

 

 

R

 

 

Blue Lead

 

T

0

Control Pair

Yellow Lead

 

 

 

R

 

 

 

 

 

 

Green Lead

Ground

 

117

Page 117
Image 117
3M 965DPS instruction manual Dead Pair Test, SmartStrap Connection