Connect the red test lead to ring of the pair, the black lead to the tip and the green test lead to ground. From the Auto Menu Screen, press the [Enter] key to start the Autotest. The Active Pair results screen will appear.

The test result values or pass/fail status will be displayed for each test. Press the [Enter] key to repeat the test. Press the [Tab] key to view the test result values for all tests.

Note: If the Power Influence measurement result is greater than 70 dBrnC (-20dBmOp), then Noise Balance will be displayed. Otherwise Longitudinal Balance will be displayed.

Press the [Tab] key to return to the pass/fail screen or [Enter] to retest.

114

Page 114
Image 114
3M 965DPS instruction manual 114