Edit the Tech ID and Job Number using the same procedure described previously. Up to
14 alphanumeric characters can be entered in each field. Use the [Tab] key to jump between highlighted boxes. Use the [Setup] key to clear both fields. The data entered into each field will remain present for every saved result until explicitly changed or cleared. In this way information that is infrequently changed (Tech ID for instance) does not need to be
At least 40 ADSL test results can be saved. The percentage of remaining memory for results storage is shown in the box at the top of the screen. The number of saved TDR or Autotest results does not impact the number of ADSL results that can be saved.
ADSL Warning Screens
ADSL warning screens are intended as informational aids and provide additional explanatory data. Warning screens can be categorized into four groups: modem information, link activation failures, connection lost, and timeouts.
84