Current

This function measures the DC current flowing through a 430 Ohm resistor inside the 965DSP. Connect the red and black leads to the pair to measure loop current.

If the Current is greater than 110 mA, you will see the following ‘Current Warning’ screen:

This screen indicates that a high current has been detected between the test leads and that the 965DSP has opened an internal relay to protect itself

from damage. Use standard safety practices for disconnecting the test leads. Press the [Enter] key to restart the 965DSP. Fix problems before restarting the current measurement again.

23

Page 23
Image 23
3M 965DPS instruction manual Current