Autotest
Use this function to perform an automatic sequence of tests on an Inactive, Active or Wideband pair. The Wideband Autotest requires the use of a Far-end Device (FED) such as a 3M FED, FED II, or CTC Smart Strap™. The Inactive Pair Autotest can be run with or without a FED. The Active Pair Autotest is performed on a working pair (without a FED) using a test line number. Certain Autotest results are compared against pass/fail limits to provide a quick-look at the pair condition. The pass/fail status is indicated in the results box by with an “OK” for pass, a “Yield” sign for marginal, and a “Stop” sign for fail. Test values are also available for inspection in the test value screen. In this screen, values that are marginal or have failed are indicated by a highlight around the result box. Refer to the tables on pages 130–131 for the tests that are performed and the tests that have pass/fail limits.
Autotests without a FED
If a FED has not been previously selected, only the Inactive Pair and Active Pair selection will be visible. Use the [Up] and [Down] keys to select one or the other. If a FED has been previously selected, press the [Tab] key to select “None” under FED Setup.
Inactive Pair Autotest (without FED)
The Inactive Pair screen displays the type of test (basic or full), the type of service (POTS), the wire gauge, FED select status, and the cable type.
Press the [Setup] key to change the Inactive pair parameters.