RFL (Resistance Fault Locate)
Use this function to locate a Resistance Fault on a pair or on a single conductor.
There are two possible hookups: Separate Pair or Single Pair. Use [Tab] to switch between the two hookups.
Separate Pair (This is the preferred hookup)
You must first use the Resistance function to determine the faulted conductor and identify a separate good pair (a pair with no faults).
Once you identify the wires, connect the shorting strap at the
Press the [RFL] key and select “Separate Pair” by pressing the [Tab] key.
The hookup screen will show the last selected wire gauge and temperature. Use the [Setup] key to change the gauge, temperature, or to enter a known distance to Strap.
Note: Either the temperature or length (distance to Strap) must be selected as unknown. Enter the pound (#) sign as the unknown.
58