Autotests with a FED

The 965DSP will perform an Inactive or Wideband Autotest with a FED, FED II or SmartStrap. From the Auto Menu screen, press the [Tab] key to go to the FED setup screen.

 

 

None

FED

FED II

SmartStrap

 

 

 

 

 

 

 

 

 

Inactive

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

Active

Yes

No

No

No

 

 

Wideband

No

Yes

Yes

Yes

 

 

 

 

 

 

 

 

Use the [Up] and [Down] keys to select a 3M FED, 3M FED II, or the CTC Smart Strap.