Self-Test Board

A self-test board is included with the 965DSP to verify the performance of Opens and RFL. This is particularly important if operating conditions (shock, temperature, etc.) have changed and you want to check the unit's accuracy.

Check Opens performance: To verify Opens, connect the red test lead to the “R” terminal, and the black test lead to the “B” terminal. Press the [Opens] key on the 965DSP. You should see the following readings for different types of cable (US and Canada).

Note: Do not connect the green test lead to the “G” terminal of the self-test board when checking Opens performance. The ‘Red to Green’ measurement will not read correctly.

Measurement

Type of Cable (US and Canada)

 

 

 

 

 

 

 

Capacity

Aircore

Jelly-filled

 

 

 

 

 

Red to Green

MIN

9.35 nf

395 ft

350 ft

or

(120 m)

(107 m)

 

 

Black to Green

 

 

 

 

MAX

.011 uF

450 ft

400 ft

 

 

(137 m)

(122 m)

 

 

 

 

 

 

 

 

Red

MIN

9.35 nf

595 ft

595 ft

(181 m)

(181 m)

 

 

to

 

 

 

 

Black

MAX

.011 uF

680 ft

680 ft

 

(207 m)

(207 m)

 

 

 

 

 

 

 

 