Category
address symbol
Name
Descriptions
Range
and
choices
Default
|
|
|
| Set the time limit to discarge it |
|
| |
|
|
| Discharge | When time is up and weighing value is | 0 to | 0 s | |
5q | not zero band, sequence error | ||||||
monitoring timer | 65535 s | ||||||
|
|
| SQ.ERR5 is displayed. |
| |||
|
|
|
|
|
| ||
|
|
|
| If 0 is set, the timer does not work. |
|
| |
|
|
| Discharge gate | Set the wating time from reacheing to | 0.1 to | 0.1 s | |
5q | zero band to closing discharge gate for | ||||||
close delay timer | 25.5 s | ||||||
|
|
| gross. |
| |||
|
|
|
|
|
| ||
|
|
| Batch finish output | Set the active (ON) time of batch finish | 0.00 to | 0.00 s | |
5q | signal. If 0 is set, output is kept until next | ||||||
on | 2.55 s | ||||||
|
|
|
| sequence. |
|
| |
5q | Discharge finish | Set the time to keep the ON for | 0.00 to | 0.00 s | |||
output on | discharge signal. | 2.55 s | |||||
|
|
|
| ||||
5q | Recipe finish output | Set the time to keep the ON for recipe | 0.00 to | 0.00 s | |||
on | finish signal. | 2.55 s | |||||
|
|
|
| ||||
5q | Mixing finish output | Set the time to keep the ON for mixture | 0.00 to | 0.00 s | |||
on | finish signal. | 2.55 s | |||||
|
|
|
| ||||
5q | Mixing time output | Set the time to keep the ON for mixture | 0 to | 0 s | |||
on | time signal. | 255 s | |||||
|
|
|
| ||||
|
|
|
| Set the time to average the result. This |
|
| |
|
|
|
| time controls precision of the result. | 00.0 to | 0.00 s | |
5q | Averaging Eval time | Refer to Eval delay timer [5q | |||||
2.55 s | |||||||
|
|
|
|
| |||
|
|
|
|
|
| ||
|
|
|
|
|
| ||
s : | second |
|
|
| |||
d: | digit |
|
|
|
| Page 117 |