Category

address symbol

Name

Descriptions

Range

and

choices

Default

 

 

 

 

Set the time limit to discarge it

 

 

 

 

 

Discharge

When time is up and weighing value is

0 to

0 s

5q

f-39

not zero band, sequence error

monitoring timer

65535 s

 

 

 

SQ.ERR5 is displayed.

 

 

 

 

 

 

 

 

 

 

 

If 0 is set, the timer does not work.

 

 

 

 

 

Discharge gate

Set the wating time from reacheing to

0.1 to

0.1 s

5q

f-40

zero band to closing discharge gate for

close delay timer

25.5 s

 

 

 

gross.

 

 

 

 

 

 

 

 

 

 

Batch finish output

Set the active (ON) time of batch finish

0.00 to

0.00 s

5q

f-43

signal. If 0 is set, output is kept until next

on

2.55 s

 

 

 

 

sequence.

 

 

5q

f-44

Discharge finish

Set the time to keep the ON for

0.00 to

0.00 s

output on

discharge signal.

2.55 s

 

 

 

 

5q

f-45

Recipe finish output

Set the time to keep the ON for recipe

0.00 to

0.00 s

on

finish signal.

2.55 s

 

 

 

 

5q

f-46

Mixing finish output

Set the time to keep the ON for mixture

0.00 to

0.00 s

on

finish signal.

2.55 s

 

 

 

 

5q

f-47

Mixing time output

Set the time to keep the ON for mixture

0 to

0 s

on

time signal.

255 s

 

 

 

 

 

 

 

 

Set the time to average the result. This

 

 

 

 

 

 

time controls precision of the result.

00.0 to

0.00 s

5q

f-48

Averaging Eval time

Refer to Eval delay timer [5q

2.55 s

 

 

 

 

f-37] and Eval conditions [5q

 

 

 

 

 

 

 

 

 

 

 

f-13].

 

 

s :

second

 

 

 

d:

digit

 

 

 

AD-4402

Page 117