Category address: [Function] - [Function setting] - [General] - [Sub-display]

Category

 

 

Range

 

address

Name

Descriptions

and

Default

symbol

 

 

choices

 

5Ubf- 1

Weighing display

0: Basic format

0 to 1

0

1: Custom format

 

 

 

 

When arranged format is used (When [5Ubf- 1] [1] ), set items to be displayed in the sub-display.

Item index number to be displayed. 32 items of name and number can be set in maximum. At odd: Input the name of the selected item using alphanumeric characters.

At even: Input the number concerning the item.

Name of the item

5ub f 1

Sub F1-3 [name]

hopper /row/col/digits

19 0 16 5

Information of key operation

Resize the item selected.

Number

Name and Number to Display the Item

Row size

Columsize

Figures

0

Not displayed

 

 

 

1

Material

 

 

 

2

Hopper

 

 

 

3

Final

 

 

 

4

Free fall

 

 

 

5

Preliminary

 

 

 

6

Optional preliminary

 

 

 

7

Over

 

 

 

8

Under

 

 

 

9

Zero Band

 

 

 

10

Full (full filling)

 

 

 

11

Tare

0 to 3

0 to26

1 to12

12

Supplementary flow open timer

 

 

 

13

Supplementary flow close timer

 

 

 

14

Automatic Free Fall Compensation

 

 

 

15

Internal reserved

 

 

 

16

Internal reserved

 

 

 

17

IDF at entrance sequence

 

 

 

18

MDF at entrance sequence

 

 

 

19

Accumulated weight

 

 

 

20

Accumulation counts

 

 

 

21

Recipe , rCode

 

 

 

22

Accumulated weight for recipe mode

 

 

 

23

Accumulation counts for recipe mode

 

 

 

Page 108

AD-4402

Page 110
Image 110
A&D PD4000243 manual 5ub f