7.3.3.Compensation Sequence

The compensation sequence is used to make up (add) the material automatically, when the result of current batch weighing is under weight.

Concerning Parameters of the Function

Storing a maximum repeat counts of compensation sequence.

[5q f-18] If number is zero, this sequence is canceled. When the result is under weight after the sequence, An error SQ.ERR 2 is displayed. [Function] - [Function setting] - [Sequence] - [Control] - [Maximum number of compensation]

Setting the time to open the dribble gate.

Set the time at each material code.

[Function] - [Function setting] - [MatEDIT] - [Edit] - [Compensation flow open timer]

Setting the time to close the dribble gate.

Set the time at each material code.

When the weighing value is stable and under weight, the compensation is repeated. Take a longer time closing gate, if it does not use a stable signal.

[Function] - [Function setting] - [Material Edit] - [Edit.] - [Compensation flow close timer]

Removing the nozzle at this sequence, when the nozzle operation is used.

[5q f-12] [2] Nozzle contact stop sequence

Factory setting is "not used". When it is necessary to shift up the nozzle to reduce a weighing error, use this parameter of [5q f-12]. [Function] - [Function setting] - [Sequence] - [Control] - [Nozzle control]

AD-4402

Page 43

Page 45
Image 45
A&D PD4000243 manual Compensation Sequence