9.4. Initializing Parameters

The function initializes the parameters stored in the indicator.

The parameters are stored in the flash memory and backup RAM.

Caution

There are the kinds of reset function that must re-calibrate the indicator Note the parameters where is stored in.

Kinds of intialization mode

Kinds of intialization

 

Description

Initializing RAM

The backup RAM is reset. Zero point of gross display, tare

value zeroes.

 

Initializing material code or

Material code and recipe code is reset.

recipe code

 

 

Initializing function list

It

is reset parameters of function list in the flash memory.

Initializing caribration data

It

is reset parameters of calibration data in the flash

memory. If this function is used, calibrate the indicator.

 

Initializing all parameters

It resets all parameters.

The location of the parameters and objects of intialization mode

 

 

 

 

 

Material

Recipe

 

 

 

 

 

 

 

 

code

 

code

 

 

 

 

 

Zero

Tare

Material code

 

Accumulation data

Recipe code

 

Accumulation data

Function list

Calibration data

 

 

 

 

 

 

 

 

 

 

 

 

 

Location

Backup RAM

o

o

o

 

o

o

 

o

 

 

 

 

 

 

 

 

 

 

 

 

 

Flash memory

 

 

o

 

 

o

 

 

o

o

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mode

Initializing RAM

o

o

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Initializing material code or

 

 

o

 

o

o

 

o

 

 

 

 

 

 

 

 

 

 

recipe code

 

 

 

 

 

 

Intialization

 

 

 

 

 

 

 

 

 

 

Initializing function list

 

 

 

 

 

 

 

 

o

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Initializing caribration data

 

 

 

 

 

 

 

 

 

o

 

 

 

 

 

 

 

 

 

 

 

 

 

Initializing all parameters

o

o

o

 

o

o

 

o

o

o

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 100

AD-4402

Page 102
Image 102
A&D PD4000243 manual Initializing Parameters, Kinds of intialization mode