8.2.4.General Data Format
This format is used at command mode and jet stream mode.
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 |
R | G | R | S | 0 | 0 | 9 | 9 | , | 1 | 2 | 3 | 4 | 5 | 6 | 7 | , | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | C | L |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| R | F |
Header | Code | Weighing data | Terminator |
Header |
|
| System Monitor |
|
|
|
Command is replayed. The replayed command is 4 characters
Code
Material code or recipe code number. The code is 4 characters
Weighing data
Data uses BCD code, is 7 figures and is not include decimal point.
When data is negative, minus sign is appended to the head.
System Monitor
1 2 3 4 5 6 7 8 9
20: Stable
21: Zero band
22: Full filling
23: Full flow
20: Under
21: Internal reservation
22: Internal reservation
23: Mixture
20: Mixture finish
21: Nozzle down
22: Online
23: During weighing sequence
20: Zero error
21: Out of range
22: Buzzer
23: During tare
Internal reservation
Example: 23 22 21 20
1 0 1 0 = Ah
ASCII code = 3Ah.
Upper 4 bits are 3h always.
20: Medium flow
21: Dribble flow
22: Over
23: Acceptable
20: Discharge gate
21: Weighing finish
22: Recipe finish
23: Discharge finish
20: Internal reservation
21: Weighing error
22: Alarm 1
23: Alarm 2
20: Center of zero
21: Gross display
22: net display
23: During hold
Terminator | CR: 0Dh, LF: 0Ah |
CR or CR + LF |
| Page 77 |