Page 60 AD-4402
7.4.1.7.4.1.7.4.1.7.4.1. Normal Batching of ComparisonNormal Batching of ComparisonNormal Batching of ComparisonNormal Batching of Comparison Function Function Function Function
The function outputs the gate control signals that are compared setpoint and weighing
data that is accumulated materials to hopper.
When the weight increases above the setpoint, the gate control signal turns off.
When the weight decreases under the setpoint, the gate control signal turns on.
There is not direction for the weighing sequence in this function. Therefore, the
comparison is repeatable (reversible).
Concerning Parameters of the Function
Using the normal batching of comparison function
[5qf- 1] [1]Costomer programmed control
[5qf- 3] [0]Normal batch weighing
[Function] - [Function setting] - [Sequence] - [Basic]
Changing waiting time of judgment
[5qf-37]Eval delay timer
[Function] - [Function setting] - [Sequence] - [Timer]
Changing the pulse width of batch finish output
[5qf-43]Batch finish output on
The arbitrary width can be set.
If zero is set, the output keeps until next start.
[Function] - [Function setting] - [Sequence] - [Timer]
Using signals of "over", "acceptable" and "under" in the comparison function.
[5qf- 5]Comparison
[Function] - [Function setting] - [Sequence] - [Basic]
Changing the accuracy of the comparison
[5qf-48]Averaging Eval time
The average time of batch finish output is set. The output of batch
finish delays by the average time.
[Function] - [Function setting] - [Sequence] - [Timer]
Using the manual compensation
[1n f-nn] [10]Manual free fall compensation
[05 f-nn] [10]Manual free fall compensation
nn: terminal number of the I/O.
The input to control free fall by the external PLC.
[Function] - [Function setting] - [Control I/O] - [Input]