7.3.5.Discharge Sequence

The discharge sequence is used to discharge the material form the hopper and clear the hopper after finishing a batch weighing.

Concerning Parameters of the Function

Storing the time between receiving start command and opening the discharge gate.

[5q f-38] [Function] - [Function setting] - [Sequence] - [Timer] - [Discharge start delay timer]

Using the alarm for the discharge time limit.

[5q f-39] If it is over, an error SQ.ERR 7 is displayed.

[Function] - [Function setting] - [Sequence] - [Timer] - [Discharge monitoring timer]

Storing the time between cleared hopper and closed the gate.

[5q f-40] [Function] - [Function setting] - [Sequence] - [Timer] - [Discharge gate close delay timer]

Discharging it automatically when finished the weighing.

[5q f-14] When the finish signal is turned off, the discharge start timer starts. [Function] - [Function setting] - [Sequence] - [Control] - [Batch finish action]

Discharging it automatically when finished the mixture weighing.

[5q f-17] When the finish signal is turned off, the discharge start timer starts. [Function] - [Function setting] - [Sequence] - [Control] - [Recipe finish action]