Page 80 AD-4402
Control Commands
Name Code Description
CZER
Make zero display MZ #1
Make zero clear CCZR
CTAR
Tare MT #1
CCTR
Tare clear CT #1
CGRS
Change to gross display MG #1
CENT
Change to net display MN #1
CCODxxxx
Call material code CCxx #1
Call recipe code CRCDxxxx
CACC
Accumulation command AM #1
CCAC
Cancel the last result CA #1
CBAT
Batch start BB #1
CDSC
Discharge start BD #1
Recipe start CBLD
Mixture start CMIX
Re-start CRES
Stop CHLT
CSTP
Emergency stop HB #1
CDTLxxxx Accumulation data is set to 0.
Clear accumulation data
of material code DTxx Accumulation data is set to 0. #1
CETL All accumulation data is set to 0.
Clear accumulation data
of all material code ET All accumulation data is set to 0. #1
Clear accumulation data
of recipe code CDRTxxxx Accumulation data is set to 0.
Clear accumulation data
of all recipe code CERT All accumulation data is set to 0.
Reset an error CRER
No operation CNOP
xxxx: Material code or recipe code.