Category address: [Function] - [Function setting] - [Option] - [slotn] -
slot n : slot number
Category |
|
|
|
| Range |
| ||
address | Name |
| Descriptions | and | Default | |||
symbol |
|
|
|
| choices |
| ||
|
|
| When jet stream mode of Coumnication |
|
| |||
|
|
| mode [r5 f- 2] is used, the 1, 2, 3 can |
|
| |||
|
|
| select. And if freeze mode is used in jet |
|
| |||
|
|
| stream mode, output is stoped. |
|
| |||
|
|
| 1: | Weighing value |
|
|
| |
|
|
| 2: | Gross value |
|
|
| |
03 | f- 1 |
| 2: | Net value |
|
|
| |
Output data | 4: | Tare value |
| 1 to 10 | 1 | |||
04 | f- 1 |
| ||||||
| 5: Gross value/ Net value/ Tare value |
|
| |||||
|
|
|
|
| ||||
|
|
| 6: Weighing value with material code |
|
| |||
|
|
| 7: Gross value with material code |
|
| |||
|
|
| 8: Net value with material code |
|
| |||
|
|
| 9: Tare value with material code |
|
| |||
|
|
| 10: Gross value/ Net value/ Tare value |
|
| |||
|
|
|
| with material code |
|
|
| |
|
|
| 1: Stream mode |
|
|
| ||
|
|
| 2: Auto print mode |
|
|
| ||
03 | f- 2 | Comunication | 3: Manual print mode |
| 1 to 6 | 6 | ||
04 | f- 2 | mode | 4: Print at total |
| ||||
|
|
| ||||||
|
|
| 5: Jet stream mode |
|
|
| ||
|
|
| 6: Command mode |
|
|
| ||
|
|
| 1: 600 bps |
|
|
| ||
|
|
| 2: 12000 bps |
|
|
| ||
|
|
| 3: 2400 bps |
|
|
| ||
03 | f- 3 | Baud rate | 4: 4800 bps |
| 1 to 7 | 5 | ||
04 | f- 3 | 5: 9600 bps |
| |||||
|
|
|
| |||||
|
|
| 6: 19200 bps |
|
|
| ||
|
|
| 7: 38400 bps (Command mode can not |
|
| |||
|
|
|
| select) |
|
|
| |
03 | f- 4 |
| 0: Not used |
|
|
| ||
Parity check | 1: Odd |
| 0 to 2 | 0 | ||||
04 | f- 4 |
| ||||||
| 2: Even |
|
|
| ||||
|
|
|
|
|
| |||
03 | f- 5 | Charactor length | 7: 7 bits |
| 7, 8 | 8 | ||
04 | f- 5 | 8: 8 bits |
| |||||
|
|
|
| |||||
03 | f- 6 | Stop bits | 1: | 1 bit |
| 1 to 2 | 1 | |
04 | f- 6 | 2: 2:bits |
| |||||
|
|
|
| |||||
03 | f- 7 | Terminator | 1: CR | CR: 0Dh | 1 to 2 | 2 | ||
04 | f- 7 | 2: CR LF | LF: 0Ah | |||||
|
|
|
Page 128 |
|